True
Product Image

didoEASY M Mammo Dosemeters

£ 2,765.44 £ 2,765.44
0.0% Off

didoEASY M Mammo Dosemeters

1
(0 review)

Dosemeter Series for X-Ray Service and QA in Mammography

  • didoEASY M Model

This combination does not exist.

SKU:
RG1171
Brand: Quart


Share :

QUART didoEASY M
Basic Configuration
QUART didoEASY+ M
Added kV Measurement
QUART didoEASY++ M
Added kV and Direct-HVL Measurement
 

The QUART didoEASY meters are designed for users who emphasise high precision in dosimetric applications but do not require the performance of a full-range dosemeter package.

QUART didoEASY meters can be used to measure parameters which are essential for service and quality assurance operations at x-ray equipment such as dose, dose rate and time. Of course, as with all QUART meters – with maximum precision.

- kVp and PPV measurement available in the QUART didoEASY+ M version.

- Direct-HVL and kVp / PPV measurement available in the QUART didoEASY++ M version.

Since the meters do NOT require any pre-setting procedure, measurement results are acquired very quickly:

1. Position the detector and switch on the didoEASY meter...

2. Set the x-ray equipment to the desired parameters...

3. Expose... - and simply read all measurement information from the meter‘s display. The QUART didoEASY M meters automatically compensate for Mo/Mo beam quality. Corrections factors are provided for further radiation qualities.

Technical specifications

General Features
  • Exposures: one to acquire all parameters
  • Mode: auto-start, auto-stop & auto-reset
  • Power supply: Rechargeable Li Ion accu
  • Battery time: approx. 120 hrs. until recharge required
  • Base size: 17x7x4.5cm (LxWxH)
  • Base weight: 200 g
  • Detector size: 6.0x1.8x0.5cm (LxWxH)
  • Detector weight: negligible (!)
Specifications

 

didoEASY M    basic configuration

  • Dose: 0.2 µGy - 999 Gy (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.01 nGy)
  • Dose Rate: 0.3 µGy/s - 1 Gy/s (Uncertainty: ±5% over full range / Resolution: 0.1 nGy/s)
  • Time: 0.5 ms - 300 s (Uncertainty: ± 0,5% / Resolution: 0.1 ms)
  • Pulses: 1 - 9999 (Uncertainty: ± 1 pulse)
  • Pulse Rate: 0.1 - 250 pulses/s (Uncertainty: ± 0.05 pulses/s)

 

didoEASY+  M   - features added kV measurement 

  • Dose: 0.2 µGy - 999 Gy (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.01 nGy)
  • Dose Rate: 0.3 µGy/s - 1 Gy/s (Uncertainty: ±5% over full range / Resolution: 0.1 nGy/s)
  • Time: 0.5 ms - 300 s (Uncertainty: ± 0,5% / Resolution: 0.1 ms)
  • Pulses: 1 - 9999 (Uncertainty: ± 1 pulse)
  • Pulse Rate: 0.1 - 250 pulses/s (Uncertainty: ± 0.05 pulses/s)
  • kVp / PPV: 25 – 35 kV (Uncertainty: ±5% at calibrated reference points / Resolution: 0.1 kV); Exposure conditions: Mo/Mo; HVL 0.6 – 2.2 mm Al eq., correction factors provided for further radiation qualities

 

didoEASY++  M   - features added kV and direct-HVL measurement

  • Dose: 0.2 µGy - 999 Gy (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.01 nGy)
  • Dose Rate: 0.3 µGy/s - 1 Gy/s (Uncertainty: ±5% over full range / Resolution: 0.1 nGy/s)
  • Time: 0.5 ms - 300 s (Uncertainty: ± 0,5% / Resolution: 0.1 ms)
  • Pulses: 1 - 9999 (Uncertainty: ± 1 pulse)
  • Pulse Rate: 0.1 - 250 pulses/s (Uncertainty: ± 0.05 pulses/s)
  • kVp / PPV: 25 – 35 kV (Uncertainty: ±5% at calibrated reference points / Resolution: 0.1 kV); Exposure conditions: Mo/Mo; HVL 0.6 – 2.2 mm Al eq., correction factors provided for further radiation qualities
  • Direct-HVL: 0.1 – 11 mm Al (HVL output, Uncertainty: ±8% / Resolution: 0.1 mm Al); Internal filtration 0.1 – 12.5 mm Al equivalent; 25-40 kV range

* S A Mitchell and C J Martin, Comparison of ionisation chamber and semiconductor detector devices for measurement of the dose–width product for panoramic dental units, J. Radiol. Prot. 33 321 (2013).

>> Read more about References for QUART didoEASY M


To install this Web App in your iPhone/iPad press and then Add to Home Screen.